HOME > X-ray 3D-CT Systems
X-ray 3D-CT Systems

X-ray 3D-CT Systems



Uni-Hite System Corporation


X-ray 3D-CT Systems

Recently, in the industry such as a semiconductor, electronic parts, electronic equipment, and the batteries, X-Ray 3D-CT demands have risen.
MARUBUN help the customers through sales of the X-Ray 3D-CT systems made of UNIHITE SYSTEM Corporation.
MARUBUN is a general sales agent of UNIHITE SYSTEM Corporation.

Contact us

MARUBUN CORPORATION
Systems Sales & Marketing Div. Sales Dept.2
Industrial Systems Team 1
TEL:+81-3-3639-9823
E-mail : sanki@marubun.co.jp

3D-CT serise

High resolution 3D X-ray CT system XVA-160α
XVA-160α is high-end and high resolution X ray-CT system that installs 3D oblique CT function and corn beam CT function. XVA-160α achieved a nondestructive analysis at the Nano level.
[Feature]
  • High magnification (1600 geometrical times)
  • High Resolution - 250nm (0.25um) focus size
  • U-centric function
  • 3D oblique CT(Noix)
  • Horizontal CT(Presto)

High resolution 3D X-ray CT system XVA-160
XVA-160 is standard model of high resolution X ray-CT system that installs 3D oblique CT function.
[Feature]
  • High magnification (1000 geometrical times)
  • High Resolution - 0.4um focus size
  • U-centric function
  • 3D oblique CT(Noix)
  • Horizontal CT(Presto)

Microfocus 3D X-ray CT system XVA-G
XVA-G is general-purpose type CT system that installs 3D oblique CT function.
It is the best for the sampling inspection of the BGA mounting line.

[Feature]
  • U-centric function
  • High speed 3D oblique CT

Technology

U-centric function
A special stage mechanism that does not loose the observation point.

The inspection stage stays centered on the observation point.This mechanism allows zooming in and out, oblique observation,and rotated observation without loosing the inspection part.

3D oblique CT(Noix)
Non-Destructive Inspection of Large PCBs.

3D oblique CT(Noix) can take pictures of samples with large aspect ratios, such as for large PCBs, in all 360˚ directions under the same conditions.
Tomography imaging of samples at high magnification is possible
without any special jigs: Just place the samples put on the stage.
Past Horizontal CT could not take pictures of samples like large PCBs, because most PCBs have a high aspect ratio, it is difficult to take a picture from the 360˚ directions under the same conditions.